NXP-TM-AES / NXP-TM-AES-PI
XIRIUM PRO US Transmitter TX Digital AES/EBU Input Module, including NKXPF-5-15-3
Input and output module options handle common signal type
Whether the signal type is analog, digital (AES/EBU) or Dante, XIRIUM PRO offers modules to accept any of them. Signal types may also be converted from one type to another, simply by selecting the appropriate module. Need to transmit an analog signal and plug into a digital input? No problem. Select an analog input module for the transmitter, and the AES digital output module for the receiver. In fact, every receiver in a system can use a different output module, allowing for signal conversion to the type used by your device.
Technical Information show hide
Product specific
-
IEEE 802.11a, UNII-1 band from 5200 MHz to 5250 MHz (channels 40-48) and UNII-3 band from 5725 MHz to 5825 MHz (channels 149-165), license-free
Proprietary (DiWA technology)
Conducted 26 dBm / 32 dBm (with 6 dBi antenna) / 35 dBm (with 9 dBi antenna), FCC compliant
Up to 1000 m point to point (LOS), longer range depending on obstacles, reflexions, interferences, XROC mode
-
< 0.01 % @ 1 kHz, 4 dBu / < 0.05 % @ 20 Hz – 10 kHz, 4 dBu
+0.5 dB / -1.5 dB @ 20 Hz – 20 kHz ref. 1 kHz
> 105 dB @ 1 kHz, A-weighted
< -80 dB @ 20 kHz
2
1 (XROC mode)
24 bit
48 kHz
3.6 msec (analog to analog)
Compression-free, no reduction of converted data
32°F to +122°F / 0°C to +50°C
-4°F to +176°F / -20°C to +80°C
-
24 bit / 48 kHz according to AES3-2003
proprietary protocol by Audinate®
-
Omni-directional, 6 dBi, 25° Elevation and 360° Azimuth, N-connector male (direct mount)
1/2 wave dipole with SMA female connectors
2
1 (XROC mode)
-
Input Level
Input Imp. |
Rated Source Imp. |
Max. * | Connector type |
10 kOhm | 1000 Ohm | 22 dBU | XLR |
* maximum input level before signal overflow,
0 dBu = 0.775 V rms
LEDs: Power ON / Start Up / Low Battery Status / XROC mode / Linking Process / Audio transmission
Power ON / Linking Process / XROC mode
NXP-TM-AES: Mains input over powerCON TRUE1 (100-240 VAC 50/60 Hz) or internal battery (typical battery runtime 10 hours, depending on type of module,
transmission power settings, XROC mode, number of charging cycles and operating temperature)
NXP-TM-AES-PI: Mains input over powerCON TRUE1 (100-240 VAC 50/60 Hz)